Browsed by
Author: Andrei Moldoveanu

USGBC and the “public” review process

USGBC and the “public” review process

I’ve been involved this year with the “public” part of the process that supposedly gets the USGBC’s LEED rating points approved.  As a result I’m wondering if it’s only a good PR to make people feel they can have a saying in the process or a Kafkaesque bureaucratic process inspired by his novel The Castle. First off, the process opens…

Read More Read More

IGCC may need to consider the facts of life

IGCC may need to consider the facts of life

IGCC is heading towards the final public hearings in November.  One article in particular Article 505.1.1 Service Life, raised a lot of objections during the second IGCC  public review  since it asks that all electrical products must have a design life of minimum 25 years.      NEMA proposed that the “electrical” category be removed altogether from the requirement.  While many electrical…

Read More Read More

USGBC and challenges to its LEED point High Performance Buildings Rating System

USGBC and challenges to its LEED point High Performance Buildings Rating System

The U.S. Green Building Council (USGBC) has been recently challenged by a third-party to a LEED certification. It involves an appeal of the Gold building certificate awarded to Northland Pines High School in Eagle River, Wis in 2007. The appellants contend the design and construction of the school did not meet a number of prerequisites for the certification.  The appellants…

Read More Read More

Smart grid impact deepens

Smart grid impact deepens

The promise of a more efficient electric power grid is coming closer and closer to reality.  Many of the overarching concepts have been defined and now considerable activity is underway to define the myriad of interactions between the multitude of actors in this huge play.  One such activity, sponsored by North American Energy Standards Board (NAESB)  is just getting started…

Read More Read More

Smart Receptacle’s time has come

Smart Receptacle’s time has come

The High Performance Building is coming along quite well technologically.  New ideas and products show up like mushrooms after the rain.  One product area where we’ll definitively see improvements is the good old receptacle and its matching plug.  In addition to already familiar functions like GFCIs for personal protection we’ve seen recently product proposals offering several additional benefits: Safety Thermal…

Read More Read More

AWG Wire Sizing System goes Global

AWG Wire Sizing System goes Global

On September 29th 2009 the IEC published IEC/TR 62602 Conductors of insulated cables – Data for AWG and KCMIL sizes.     The informative publication completed the first of several stages in a process initiated by NEMA members to ultimately produce a normative IEC standard for both metric based and N. American sized conductors.   A good reason to celebrate this important achievement…

Read More Read More

Tamper-Resistant Receptacle Requirements in 2008 NEC Adopted in 29 States

Tamper-Resistant Receptacle Requirements in 2008 NEC Adopted in 29 States

With 30 states having completed adoption processes for the 2008 National Electrical Code® (NEC), support for section 406.11, which requires tamper-resistant receptacles to be installed in new homes, has been overwhelmingly positive. Twenty-nine of the 30 states have adopted the 2008 NEC with the tamper-resistant Code intact. These include: Alaska, Arkansas, Colorado, Georgia, Idaho, Iowa, Kentucky, Maine, Massachusetts, Minnesota, New…

Read More Read More

Where Do You Plug-in Your Electric Vehicle?

Where Do You Plug-in Your Electric Vehicle?

Plug-in vehicles, either hybrid or all electrical, are just around the corner.  The big question is how are they going to be recharged? The answer depends a lot on who you are asking.  In the US the most significant effort is made by the Society of Automotive Engineers (SAE International).  A number of standards are in the works to cover…

Read More Read More

Low Hanging Sustainability Fruit: Energy Efficiency

Low Hanging Sustainability Fruit: Energy Efficiency

Energy consumption is by far the low hanging fruit on the sustainability tree.  Since, according to Energy Information Administration, a whopping 65% of the energy produced by mostly non-renewable sources is lost in conversion processes, it stands to reason to look closer at these conversions and develop more efficient technologies to get what we need.   Seen from this perspective…

Read More Read More

HPB Congressional Caucus Issues Recommendations on Federal Buildings Acquisitions

HPB Congressional Caucus Issues Recommendations on Federal Buildings Acquisitions

Several days ago the High Performance Building Congressional Caucus issued a series of recommendations regarding Producing High-Performance Federal Buildings.  The first one on the list asks Congress to require that for all Acquisitions of Federal Buildings True Life-Cycle Analysis and Decision – Making be performed.  The second would require total building commissioning for all the federal Building Stock. When translated into…

Read More Read More